Pump Controller History
The advent of water fed pole (WFP) window cleaning radically changed the window cleaning industry by allowing people to work from ground level. Early WFP systems consisted of a water tank, battery, pump and pole. Whilst being safer and giving time savings, there were some issues.
It was common for pumps to fail after a short period of time as either the pump motor or pump pressure switch would burn out. To stop the pump and thus water flow, you had to either twist or kink the hose. Even with the flow stopped at the brush head the pump would continue to work against the restriction, building up the pressure in the system to a point where the pump pressure switch would activate. At this point maximum current would be passing through the pump. This meant that as the pressure switch opened, it would arc which would eventually lead to failure and the high pressure in the system which would wear out the connections and hoses quicker. This would cause pitting of the contacts that would eventually lead to failure. In addition the high pressure in the system meant that connections and hoses would wear out quickly, leading to lost working time whilst they were repaired or replaced. Water usage was also high.
In late 2004 we were approached by a cleaning company in the south east of England to address these problems. They had realised that if the speed of the pump could be controlled, there would be many benefits:
- Less wear and tear on the pump
- Extended life of the pump motor
- Less current drawn from the battery, meaning the charge lasts longer
- Reduced pump speed, meaning less water is used and therefore more jobs from the same tank
The first version was an analogue controller that simply turned the pump on or off and regulated the speed of the pump which used less water, pump reliability was improved and fittings lasted longer.
The pump controller developed and eventually did not rely on the pump pressure switch to stop the pump when the water flow stopped. Having the ability to detect pressure and to stop the pump gave many benefits. Referred to as Dead End (DE), the controller stopped the pump when the water flow was stopped at the pole. With DE, the pump was no longer under full load when it stopped. One of the advantages of this was that less energy was drawn from the battery. Also, as the controller stopped the pump well before the pump pressure switch would have done, the strain on the pump motor was reduced.
Then came the digital displays which provided the user with more information. These innovations led to distributors asking us for controllers that would be able to charge a battery, control the filling of a water tank, or control a hot water system. The latest generation of controllers are a world away from the early analogues, as they not only control the pump speed but are in fact sophisticated tools to help manage the whole system. Take a look at our range of V16 pump controllers on our website
The latest generation of controllers are a world away from the early analogues, as they not only control the pump speed but are in fact sophisticated tools to help manage the whole system. Please take a look at the full range of controllers contained on these pages.